Laminate reference
Isola 185HR
εᵣ 4.17 · Df 0.016 · Tg 185 °C
Dk 4.17 / Df 0.016 at 1 GHz.
- Manufacturer
- Isola
- Dielectric constant εᵣ
- 4.17
- Dissipation factor Df
- 0.016
- Glass transition Tg
- 185 °C
- Categories
- Standard FR-4, High-Tg / reliability
- Dk basis
- Datasheet
- Df basis
- Datasheet
Prepregs
Pressed thickness per ply by glass style.
| Designation | Glass | Dielectric | Notes |
|---|---|---|---|
| 185HR-106 | 106 | 0.051 mm | High resin, thin |
| 185HR-1080 | 1080 | 0.076 mm | Most common thin PP |
| 185HR-2113 | 2113 | 0.090 mm | Medium |
| 185HR-2116 | 2116 | 0.115 mm | Standard build-up |
| 185HR-1506 | 1506 | 0.165 mm | Thicker filler |
| 185HR-7628 | 7628 | 0.191 mm | Thick / cost effective |
Cores
Dielectric thickness of the laminate alone, and the finished core with copper on both faces.
| Designation | Dielectric | +2 × 0.5 oz | +2 × 1 oz | +2 × 2 oz |
|---|---|---|---|---|
| 185HR-0.05 | 0.051 mm | 0.087 mm | 0.121 mm | 0.191 mm |
| 185HR-0.10 | 0.100 mm | 0.136 mm | 0.170 mm | 0.240 mm |
| 185HR-0.13 | 0.130 mm | 0.166 mm | 0.200 mm | 0.270 mm |
| 185HR-0.15 | 0.150 mm | 0.186 mm | 0.220 mm | 0.290 mm |
| 185HR-0.20 | 0.200 mm | 0.236 mm | 0.270 mm | 0.340 mm |
| 185HR-0.25 | 0.250 mm | 0.286 mm | 0.320 mm | 0.390 mm |
| 185HR-0.30 | 0.300 mm | 0.336 mm | 0.370 mm | 0.440 mm |
| 185HR-0.36 | 0.360 mm | 0.396 mm | 0.430 mm | 0.500 mm |
| 185HR-0.41 | 0.410 mm | 0.446 mm | 0.480 mm | 0.550 mm |
| 185HR-0.51 | 0.510 mm | 0.546 mm | 0.580 mm | 0.650 mm |
| 185HR-0.71 | 0.710 mm | 0.746 mm | 0.780 mm | 0.850 mm |
| 185HR-1.00 | 1.000 mm | 1.036 mm | 1.070 mm | 1.140 mm |
| 185HR-1.20 | 1.200 mm | 1.236 mm | 1.270 mm | 1.340 mm |
| 185HR-1.50 | 1.500 mm | 1.536 mm | 1.570 mm | 1.640 mm |
| 185HR-1.55 | 1.550 mm | 1.586 mm | 1.620 mm | 1.690 mm |
Typical values from manufacturer datasheets and IPC-4101 nominals, at the frequency the manufacturer publishes. Confirm the exact grade, glass style and pressed thickness with your fabricator.