PCB Starting Point

Laminate reference

DuPont Pyralux AC

εᵣ 3.7 · Df 0.003 · Tg 280 °C

All-polyimide single-sided clad, adhesiveless. Tg 280°C by TMA. Dk 3.7 / Df 0.003 at 1 MHz, measured on AC121200RY. UL 94, IPC-4204/25.

Manufacturer
DuPont
Dielectric constant εᵣ
3.7
Dissipation factor Df
0.003
Glass transition Tg
280 °C
Categories
Flex / rigid-flex
Dk basis
Datasheet
Df basis
Datasheet
Dk / Df measured at
1 MHz
X / Y CTE
19 ppm/°C
Bonding method
Separate bondply required

Cores

Dielectric thickness of the laminate alone, and the finished core with copper on both faces.

DesignationDielectric+2 × 0.5 oz+2 × 1 oz+2 × 2 oz
AC-091200EN0.012 mm0.048 mm0.082 mm0.152 mm
AC-121200EM0.012 mm0.048 mm0.082 mm0.152 mm
AC-121200RY0.012 mm0.048 mm0.082 mm0.152 mm
AC-181200EM0.012 mm0.048 mm0.082 mm0.152 mm
AC-181200RY0.012 mm0.048 mm0.082 mm0.152 mm
AC-351200RHV0.012 mm0.048 mm0.082 mm0.152 mm
AC-122000EM0.020 mm0.056 mm0.090 mm0.160 mm
AC-182000EM0.020 mm0.056 mm0.090 mm0.160 mm
AC-182000RY0.020 mm0.056 mm0.090 mm0.160 mm
AC-092500EN0.025 mm0.061 mm0.095 mm0.165 mm
AC-122500EM0.025 mm0.061 mm0.095 mm0.165 mm
AC-122500RY0.025 mm0.061 mm0.095 mm0.165 mm
AC-182500EM0.025 mm0.061 mm0.095 mm0.165 mm
AC-182500RY0.025 mm0.061 mm0.095 mm0.165 mm
AC-352500EY0.025 mm0.061 mm0.095 mm0.165 mm
AC-352500RF0.025 mm0.061 mm0.095 mm0.165 mm
AC-352500RHV0.025 mm0.061 mm0.095 mm0.165 mm
AC-702500RF0.025 mm0.061 mm0.095 mm0.165 mm
AC-354500EY0.045 mm0.081 mm0.115 mm0.185 mm
AC-125000RF0.050 mm0.086 mm0.120 mm0.190 mm
AC-185000RY0.050 mm0.086 mm0.120 mm0.190 mm
AC-185000RF0.050 mm0.086 mm0.120 mm0.190 mm
AC-355000RF0.050 mm0.086 mm0.120 mm0.190 mm
AC-705000RF0.050 mm0.086 mm0.120 mm0.190 mm

Typical values from manufacturer datasheets and IPC-4101 nominals, at the frequency the manufacturer publishes. Confirm the exact grade, glass style and pressed thickness with your fabricator.